- Home
- About
- Contact Us
- Legal
- Sales Policies >
- UVC - Air Side - Residential & Light Commercial
- UVC-Air Side, Commercial
- UVC Tubes, Lamps by Brand
- AUV Replacement Tubes >
- UVC Tubes Steril-Aire >
- UVC Replacement Tubes, Lamps for Steril-Aire, select by picture
- UVC Replacement Tubes, Lamps for Steril-Aire Model RSE1
- Steril-Aire Model RSE2 Replacement Tubes
- UVC Replacement Tubes, Lamps for Steril-Aire Model RSE1
- UVC Replacement Tubes, Lamps for Steril-Aire Model RSE2
- Steril-Aire Model SE-SEN Replacement Tubes
- Steril-Aire Model SE1, SEN1, Replacement UVC Tubes, Commercial Models
- UVC Replacement Tubes, Lamps for Steril-Aire Model SE / SEN Models
- SE-SEN UVC Replacement Tubes, Lamps for Steril-Aire Model RSE1
- Steril-Aire Model DE Replacement Tubes
- Links - FAQ - Tech
- Site Map
|
 |
 |
|
 |
| |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
UVC "Kits" are easy to Install In your Home Furnace or Split System. Our
UVC Kits are shipped with a power cord to simply plug into any standard wall outlet. If you prefer they can be wired
to your Furnace disconnect swith. If you are not comfortable with this method we recommend you hire a
local hvac service company. In all cases the UVC Units should be wired to be lit 24/7/365. They
consume the same energy as a standard lamp light bulb and provide continuous protection against mold, bacteria and even the
common cold and flu viruses. As air passes through your hvac system, the UVC Energy instantly kills existing airborne
microbes or renders them incapable of reproducing by disrupting the DNA cell. Available in multiple configurations
of single and dual-lamp fixtures, our UV germicidal products can be used for any type furnace coil type.
|
Rating:
BEST - "A" Coils. Most Common Unit. Highest Ouput for Superior Air Disinfection. Install Time: 30-60 Minutes. - This picture shows our Model Sapphire 2-Tube SA2
Unit Mounted on a Common "A" Coil that is very common in most Residential to Light Commercial Furnaces.
Mounted at the Top Apex of the "A" Coil any mold or bacteria that may blow off the coil will be
killed with our Superior "Independently Certified" Very High Output UVC Emitters. Required: Drill
(2) 1" Holes using the Power Supply to mark your mounting holes, Mount the Control Box with the Supplied Standard
Sheet Metal Screws, Insert the UVC Tubes and wire power using the supplied "Wiring Kit" that simply is connected
to a Standard 15 AMP Plug or your power lead on your Furnace Main Disconnect Switch. It is highly recommended you keep your
fixture lit 24/7/365 days and not wire it to cycle it on and off. | | Rating: BEST. Used for Flat Coils and
Added Air Disinfection in the Return Duct for Severe Allergies. Install Time: 30-60 Minutes. This
picture shows our Model SA1 Series Tube Unit Mounted IN-DUCT (on the return air side) for Residential to Commercial
Split System Applications. Primary unit should be mounted on the Leaving Air Side of a
"V" Coil or "Flat Coil" of the air discharge side. Our Duct mounted unit, as shown can be used in
the case of severe allergies. - Required: Drill (2)
1" Holes using the Power Supply to mark your mounting holes, Mount the Control Box with the Supplied Standard Sheet
Metal Screws, Insert the UVC Tubes and wire power using the supplied "Wiring Kit" that simply is connected to a
Standard 15 AMP Plug or your power lead on your Furnace Main Disconnect Switch. It is highly recommended you keep your fixture
lit 24/7/365 days and not wire it to cycle it on and off. |
| Rating: Good to Economy. Used for Flat
Coils and Added Air Disinfection for Allergy Added Protection. Install Time: 30-60 Minutes. These
Schematics show how our Single Tube Units are installed in units with Flat or newer V-Type Coils. There are cases on very
small units where our 2-Tube unit will not fit so a Qty of (2) Single-Tube may need to utilized as shown. GOOD: Model
EL1-RPT Series. < shop > ECONOMY: Model EL1-14/24 Series. < shop > - Required: Drill
(1) 1" Holes. Mount the Control Box with the Supplied Standard Sheet Metal Screws, Insert the UVC Tubes and wire power
using the supplied "Wiring Kit" that simply is connected to a Standard 15 AMP Plug or your power lead on your Furnace
Main Disconnect Switch. It is highly recommended you keep your fixture lit 24/7/365 days and not wire it to cycle it on and
off. |
|
|
Commercial: AHU UVC, Rooftop
Installs < click here >
|
| |
|
|
|